BMTZL - H4463 NICAD BATTERY, SEALED
- MSDS: BMTZL
- Manufacturer: ALEXANDER MFG CO
- Product Name: H4463 NICAD BATTERY, SEALED
- National Stock Number: 6140-01-114-0765
Product Identification
Product ID:H4463 NICAD BATTERY, SEALED
MSDS Date:06/01/1994
FSC:6140
NIIN:01-114-0765
MSDS Number: BMTZL
Responsible Party
MASON CITY, IA 50401-5662
US
Emergency Phone: 515-423-8955
Info Phone: 515-423-1161
Preparer: UNREADABLE
Cage: 56469
Contractor
Telephone: 914-241-1103
Cage: 57932
Ingredients
CADMIUM (SARA III) AND CADMIUM HYDROXIDE
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: < 15%
OSHA PEL SEE 1910.1027
ACGIH TLV: 0.01 MG/M3 DUST;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
NICKEL (SARA III) AND NICKEL HYDROXIDE
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: < 30%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 2-4%
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
COBALT HYDROXIDE
CAS: 21041-93-0
Fraction By Weight: , 1%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:IF THE BATTERY BREAKS OPEN, THE
CONTENTS MAY CAUSE: ACUTE-EYES: SEVERE IRRITATION & CHEMICAL BURNS.
SKIN: CHEMICAL BURNS, NICKEL CONTACT MAY CAUSE DERMATITIS. CHRONIC
OVEREXPOSURE-CADMIUM: POSSIBLE LU NG/ KIDNEY DAMAGE. NICKEL:
POSSIBLE LUNG DAMAGE. TARGET ORGANS: SKIN, EYES.
Explanation of Carcinogenicity:CONTAINS CADMIUM [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:IF THE BATTERY BECOMES OPEN, THE CONTENTS MAY
CAUSE SERIOUS LOCALIZED BURNS. CONTENTS INCLUDE NICKEL, CADMIUM,
AND POTASSIUM HYDROXIDE. UNDER NORMAL USE THIS BATTERY DOES NOT
RELEASE TOXIC MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:CONTACT A PHYSICIAN. EYES: FLUSH WITH WATER FOR 15 MINUTES.
SKIN: WASH WITH PLENTY OF WATER. MILD ACID MAY BE USED TO
NEUTRALIZE. INHALATION: REMOVE TO FRESH AIR. INGESTION: CONTACT A
PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS IF
LARGE QUANTITIES OF BATTERIES ON FIRE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.
Accidental Release
Spill Release Procedures:ELECTROLYTE, POTASSIUM HYDROXIDE IS CAUSTIC.
DO NOT ALLOW SKIN OR EYE CONTACT. FLUSH WITH WATER. THERE IS ONLY A
TRACE AMOUNT OF POTASSIUM HYDROXIDE AVAILABLE IN THE BATTERY.
Neutralizing Agent:MILD ACID
Handling
Handling and Storage Precautions:DO NOT INCINERATE OR MUTILATE; MAY
BURST RELEASING TOXIC MATERIAL (CADMIUM FUMES).
Other Precautions:DO NOT SHORT CIRCUIT THE BATTERY, IT MAY CAUSE BURNS
WHEN IN CONTACT WITH THE SKIN OR EYES.
Exposure Controls
Respiratory Protection:NONE SPECIFIED BY MANUFACTURER.
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:EYES WASH STATION AND SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NOTE: ALEXANDER MFG. CO. CONSIDERS THIS BATTERY AN ARTICLE AS DEFINED
IN 29 CFR 1910-1200 SECTION (C). THIS BATTERY DOES NOT RELEASE OR
OTHERWISE RESULT IN EXPOSURE TO A HAZARDOUS CHEMICAL UNDER THE C
ONDITIONS OF YOUR INTENDED USE.
Chemical Properties
HCC:Z5
Appearance and Odor:EACH CELL IS SEALED ENCLOSING A NICKEL, AND A
CADMIUM ELECTRODE, DRY ELECTROLYT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:BURNING (FIRE), RUPTURING
Hazardous Decomposition Products:CADMIUM FUMES MAY BE RELEASED DURING A
FIRE.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL ENVIRONMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.